Let's get your machine working
Dyson Cu-Beam Down light
Let's get your machine working
Dyson Cu-Beam Down light
Popular queries
Reference code:
Please select the appropriate option
Reference code:
Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
Replacing the fuse
Reference code:
Please select the appropriate option
Please select the appropriate option
Reference code:
Please select the appropriate option
Reference code:
Check that other appliances in the room are working, such as other lights, air conditioning, fans/heaters etc.
Reference code:
This is likely to be an issue with the electrical supply and will need to be resolved by an electrician.
Reference code:
Only check the light if it is safe to do so. If there is any doubt please contact an electrician or maintenance personnel.
Reference code:
This is likely to be an issue with the electrical supply and not related to machine itself.
This issue should be resolved by an electrician.
Reference code:
Test the fuse
Turn off the light and remove power supply. Ensure that there is no power to the light before removing the fuse.
Turn the meter on and set it to OHMS.
Put one lead on each end of the fuse and check the display on the meter.
Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
Fuse type - 4 AMP 250v Fuse.
Has the fuse blown?
Reference code:
The DALI (Digital Addressable Lighting Interface) is a data protocol and transport mechanism. The common platform of DALI enables equipment from different manufacturers to be connected.
In this instance, we use this as a lighting management control system.
Reference code:
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.

Reference code:
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
Reference code:
Check that other appliances in the room are working, such as other lights, air conditioning, fans/heaters etc.

Reference code:
Dimmer types
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
Reference code:
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
Reference code:
The product needs to be installed with a compatible dimmer in order to adjust the brightness.
Compatible dimmer - OSram DALI MCU
Reference code:
Dimmer types
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
What kind of dimmer is the product installed with?
Reference code:
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.

Reference code:
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
Reference code:
The light is not compatible with AC/Mains Triac, it will need to be installed with a compatible dimmer in order to dim.
Compatible dimmer - OSram DALI MCU
Reference code:
Please note, a converter is required if an analogue dimmer is being used.
Reference code:
Please disconnect the DALI system. If the light is operational it should power on.
You may need to speak to your DALI engineer to resolve this issue.

Reference code:
As the light is working when the DALI is not connected it is likely to be an issue with the DALI system.
Please contact a DALI engineer to resolve this issue.
Reference code:
The product is not compatible with analogue controls, it will need to be installed with a compatible dimmer, or an analogue to DALI converter, in order to properly function.
Compatible dimmer - OSram DALI MCU
Reference code:
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
Reference code:
This issue can be resolved by reinstalling the light. Cu-Beam Down light is designed to be hung over a table and not used as general lighting for a room.
Please refer to the installation guide.
Reference code:
It is recommended that the lights are installed between 1 and 1.5m from the surface of a table.

What height is the light installed over the table?
We do not advise customers to replace the wires as this will invalidate the guarantee. The wires used are to an exact Dyson specification.
Reference code:
The trim blades are the four plastic blades that connect to the rectangular baffle of the Down light.

To check the blades have been set up correctly, please view the installation guide.
Reference code:
Please refit the Blades as per the installation guide.
Reference code:
This issue could be caused by the table surface.
Please note, the Cu-Beam downlight is not suitable for use over glass or reflective surfaces.
Reference code:
Dimmer types
Analogue dimming - this is usually referred to as 1-10v dimming.
DALI - A lighting management control system.
AC mains/TRIAC - AC/TRIAC dimmers are designed for resistive loads such as incandescent or halogen lights. These phase controlled dimmers are not compatible with LEDs since LEDs do not appear as a resistive load.
Reference code:
The product needs to be installed with a compatible dimmer in order to adjust the brightness.
Compatible dimmer - OSram DALI MCU
Reference code:
Please consult an electrician as to whether the light has been installed with a compatible dimmer.
Reference code:
Please select the appropriate option
Reference code:
Your Dyson Cu-Beam light will have been provided with 4m of cable.
Reference code:
We do not advise customers to replace the wires as this will invalidate the guarantee. The wires used are to an exact Dyson specification.
The Dyson Cu-Beam lights are only approved for use with the supplied cable. This cable is to an exact Dyson specification. Replacing the cables will invalidate the guarantee.
Reference code:
Test the fuse
How to test a fuse:
Turn off the light and remove power supply. Ensure that there is no power to the light before removing the fuse.
Turn the meter on and set it to OHMS.
Put one lead on each end of the fuse and check the display on the meter.
Please note; All electrical installation and repair work should be carried out by a qualified electrician in accordance with current local codes or regulations.
Fuse type - 4 AMP 250v Fuse.
Has the fuse blown?
Reference code:
Please select the appropriate option
Reference code:
Installation video
Is there anything else we can help you with?
Reference code:
Installation guide
The installation guide can be found on the above link.
Reference code:
Please select the appropriate option
We need a little more information to help us solve your issue.
Please contact our customer service team on 01-475-7109, or directly on Live Chat through our Digital Assistant by clicking the purple icon at the bottom of the page. You can start a conversation with an Expert by clicking the agent icon at the bottom left of the chat window.
We're glad the problem's been solved.
Please let us know if there's anything else we can help you with.
The Dyson guarantee

'How to ' videos and tips
To help you get the most from your machine. Quick and easy.

Exclusive owner benefits
Priority access to previews of new Dyson technology, events and offers.

Expert advice. 7 days a week.
Freephone and live chat. The right advice for your machine, from real Dyson people.

Hassle-free repairs and replacement
Free replacement parts or repairs during your guarantee period. And if we can’t repair it, we’ll replace it.
Please get in touch.
Our experts are ready to help you.
Call us free on
01-475-7109
UK based helpline open
8:00am- 8:00pm Monday to Friday
8:00am- 6:00pm Saturday and Sunday
Further help
Dyson Cu-Beam Down light